光伏组件iec标准怎么区分a,b类
应用等级的分类是根据应用的环境来定义的:
Class A: General access, hazardous voltage, hazardous power applications
Modules rated for use in this application class may be used in systems operating at greater than 50 V DC or 240 W, where general contact access is anticipated. Modules qualified for safety through this part of IEC 61730 and IEC 61730-2 and within this application class are considered to meet the requirements for safety class II.
Class B: Restricted access, hazardous voltage, hazardous power applications
Modules rated for use in this application class are restricted to systems protected from public access by fences, location, etc. Modules evaluated within this application class provide protection by basic insulation, are considered to meet the requirements for safety class 0.
Class C: Limited voltage, limited power applications
Modules rated for use in this application class are restricted to systems operating at less than 50 V DC and 240 W, where general contact access is anticipated. Modules qualified for safety through this part of IEC 61730 and IEC 61730-2 within this application class are considered to meet the requirements for safety class III.
UL认证适用于美国,TUV认证适用于德国和欧洲,IEC认证适用于全球!下面是各认证的说明
IEC
IEC即International ElectrotechnicalCommission,国际电工委员会,IEC标准的权威性是世界公认的。IEC每年要在世界各地召开一百多次国际标准会议,世界各国的近10万名专家在参与IEC的标准制订、修订工作。
TUV
TüV (Technischer überwachüngs-Verein) 在英语中意为技术检验协会(Technical Inspection Association ) 。 TüV标志是德国TüV专为元器件产品定制的一个安全认证标志,在德国和欧洲得到广泛的接受。
UL
UL是美国保险商实验室(Underwriter Laboratories Inc.)的简写。UL安全试验所是美国最有权威的,也是世界上从事安全试验和鉴定的较大的民间机构。
应用
适用于光电系统互连线路(接地和不接地的),也符合部分(NEC), NFPA 70的要求。
技术资料
额定电压: 600 V AC
测试电压: AC 3.0 KV
温度等级: -40℃~90℃ 干或湿
耐日光
燃烧等级: UL 1685 FT1
产品描述
导体:绞合镀锡铜 参照IEC 60228 class 5
绝缘材料: XLPE
被覆材料: XLPE
颜色: 黑色和红色
行业标准
UL 4703, 文件号E326179
IEC标准为:
以不大于500V•s-1的速率增加绝缘测试仪的电压,直到等于1000V加上两倍的系统最大电压(即由制造商标注在组件上的最大系统电压)。如果系统的最大电压不超过50V,所施加的电压应为500V。维持此电压1min。
UL标准为:
在活动部分和可接触的导电部分以及活动部分和暴露的不导电的表面间的绝缘性和间距应该能承受两倍于系统电压加上1000V的直流电压,并且两部分间的漏电电流不能超过50uA。电压施加于两个电极之间。
除外:对于额定电压小于等于30V的电池板系统,施加电压为500V。
两个标准的测试条件基本是一样的,唯一的区别在于IEC是最大电压不超过50V,所施加的电压应为500V。维持此电压1min。而UL的是额定电压小于等于30V的电池板系统,施加电压为500V。
对于25年的衰减不超过20%的研究,你可以查阅一下NASA的JPL实验室在1975年左右开始的平板晶硅组件研究,目的在于降低成本及寿命预期分析。
The Flat-Plate Solar Array (FSA) Project, funded by the U.S. Government and managed by the Jet Propulsion Laboratory, was formed in 1975 to develop the modulelarray technology needed to attain widespread terrestrial use of photovoltaics by 1985. To accomplish this, the FSA Project established and managed an Industry, University, and Federal Government Team to perform the needed research and development.
JTL预期寿命是20年,后来到1983年的时候预期30年。
根据是一系列的加速老化试验推论及9年的户外试验综合分析所得。
第二,哪个标准也没说质保25年,IEC和TUV标准是讲的是25年衰减不超过20%,超过20%被认为寿命到期,但还是能够发电的,不过中国的太阳能发展还没到25年,也没这方面的数据,据说日本夏普的太阳能电池板25年后的衰减才4%
下面是2014年3月21日,国家能源局引用的一段内容:
“鉴衡认证中心的一份报告也显示,目前光伏电站存在的问题主要集中在设备质量、电站设计、电站施工和电站运维等方面。“通过对425个电站的测试,发现光伏组件主要存在热斑、隐裂和功率衰减等质量问题,像功率衰减,我们去年现场测试的11个大型地面电站运行一年期左右的组件中,在考虑了设备不确定度后发现,51%的组件衰减在5%-10%之间,其中约30%的组件功率衰减超过10%,8%的衰减超过20%。”
所以,并没有哪个具体标准能表明,回答完毕。
看要电站现场测试还是实验室内的组件检测,我们跟第三方打交道比较多,目前主流的第三方也是用的我们的光伏检测仪器,比较权威的是南德,莱茵,中认,中检,国内的有英格尔 挪亚,剩下的还有SGS 德凯等
对于25年的衰减不超过20%的研究,你可以查阅一下NASA的JPL实验室在1975年左右开始的平板晶硅组件研究,目的在于降低成本及寿命预期分析。
The Flat-Plate Solar Array (FSA) Project, funded by the U.S. Government and managed by the Jet Propulsion Laboratory, was formed in 1975 to develop the modulelarray technology needed to attain widespread terrestrial use of photovoltaics by 1985. To accomplish this, the FSA Project established and managed an Industry, University, and Federal Government Team to perform the needed research and development.
地面光伏(PV) 组件 光伏组件设计资质及型式认可的增加信任的指南
说明:IEC(国际电工委员会)标准,IEC技术规范(Technical Specification——TS),即IEC/TS
相当于我国标准的指导性技术文件(GB/Z)
EMC of CE ( IEC 61000-6-3/ IEC 61000-6-1) 电磁指令
CE LVD(IEC62109-1 2010)安全标准
DIN V VDE V 0126-1-1 (VDE V 0126-1-1):2006并网标准
如果你需要欧洲国家光伏逆变器认证可咨询。BV 国际检验集团电话0769-85935656-8065,只需一次测试可同时得到欧洲20多个国家的并网证书